DESCRIPTION

It has long been a fact that the weakest link in any clean-in-place (CIP) tank washing operation is monitoring what is taking place inside the tank. Traditional sensing methods have been rejected because they require penetrations into the tank. The APCS-2000 system goes beyond traditional sensing methods to monitor and evaluate the washing process inside the tank from outside of the tank.
The APCS-2000 system play an essential role in helping industry minimize chemical and energy utilization while maintaining the high standards imposed on the tank washing processes.
The APCS-2000 system can be adapted to virtually any tank configuration, large or small, simple or complex, easy or difficult. In a business climate that puts a premium on cost savings and environmentally friendly processes, manufacturing facilities that use the APCS-2000 system can give themselves a competitive advantage.
The system capability to drive a single sensor to monitor one cleaning head with four digital outputs to signal alarms andone digital input for optional external signal to signal start and stop of the cleaning cycle. It has an ethernet interface for connection to network and the system logs data of monitored cleaning cycles.
Thanks to its non-intrusive nature, APCS-2000 performs equally well in
– High– and low-temperature environments (up to 162 (C)/325 (F) )
– Pressurized CIP operations
- Caustic cleaning solutions
SPECIFICATIONS

System Power
Voltage: 24vdc +/- 15% @ .25 amp
Power consumption: 5.1 watts
Enclosure
Material: Glass Reinforced Polyester (RAL7001 grey)
IP Rating: 67
Certifications: ATEX EEx’e’ BS EN 50019 (Zone 1 & 2) ATEX EEx’nA’ BS EN 50021 (Zone2) NEMA 4X (CSA, UL & FM) (Class 1 division 2) GOST-R Ex’e’ (Zone 1 & 2)
Dimensions (WxHxD): 6.3 x 6.3 x 3.54 (in), 160 x 160 x 90 (mm) Mounting (WxH): 5.5 x 7.1 (in), 140 x 180 (mm)
Operating Temperature
Electronics Unit: -4 to +140 (F), -20 to 60 (C)
Sensor: -65 to +250 (F), -54 to +121(C)
Alarm Outputs
Signalling Device: relay contacts
Number of Outputs: 4 electrically isolated
Arrangement: 1 Form C
Switching Pwr (resistive): 60W, 62.5VA
Switching Volt (resistive): 220 V DC, 250 V AC / 50/60 Hz Switching Current: 1 Amp (Max)
Carrying Current: 1.5 Amp (Max)
Contact Type: SPST Normal Open
Sensor Input
Number of Channels: 1
Pickup Type: Two-wire, ICP, loop powered
Sensor Power: Internally generated 4 mA
Distance Sensor to EU: 500 ft, (150 m) Max
Ethernet Interface
Type: TCP/IP
Standards: IEEE 802.3 (10 BaseT)
Speed: 10 Mbps
Network able: Yes
Interconnect Cabling: Cat 5e or better, (100 meters max).
|
|
KEY FEATURES

APCS-2000 detects:
– Rotation
– Spray Loss
– Spray Pressure Variations
– Rotational Frequency Variations
|
|